Zeile 49: Zeile 49:
 \\ \\
 Supported formats for data point-type "object": Supported formats for data point-type "object":
 +
 +===Messages===
 +^Name  ^Typ ^Descrition^
 +^M_SP_NA_1|1|single event|
 +^M_DP_NA_1|3|double event <sup>4)</sup>|
 +^M_ST_NA_1|5|state switching event|
 +^M_ME_NA_1|9|measured value, normalized value <sup>2)</sup>|
 +^M_ME_NB_1|11|measured value, scaled value <sup>2)</sup>|
 +^M_ME_NC_1|13|measured value, floating point number with single precision <sup>3)</sup>|
 +^M_SP_TB_1|30|single event with timestamp CP56Time2a|
 +^M_DP_TB_1|31|double event with timestamp CP56Time2a <sup>4)</sup>|
 +^M_ST_TB_1|32|state switching event with timestamp CP56Time2a|
 +^M_ME_TD_1|34|measured value, normalized value with timestamp CP56Time2a <sup>2)</sup>|
 +^M_ME_TE_1|35|measured value, scaled value with timestamp CP56Time2a <sup>2)</sup>|
 +^M_ME_TF_1|36|measured value, floating point number with single precision with timestamp CP56Time2a <sup>3)</sup>|
 +^M_IT_NA_1|15|counter values|
 +^M_IT_TB_1|37|counter values with timestamp CP56Time2a|
 +===Commands===
 +^Name<sup>1)</sup>  ^Typ ^Description^
 +^C_SC_NA_1|45|single command|
 +^C_DC_NA_1|46|double command <sup>5)</sup>|
 +^C_RC_NA_1|47|state switch command|
 +^C_SE_NA_1|48|setpoint command, normalized value <sup>2)</sup>|
 +^C_SE_NB_1|49|setpoint command, scaled value <sup>2)</sup>|
 +^C_SE_NC_1|50|setpoint command, floating point number with single precision <sup>3)</sup>|
 +^C_SC_TA_1|58|single command with timestamp CP56Time2a|
 +^C_DC_TA_1|59|double command with timestamp CP56Time2a 5)|
 +^C_RC_TA_1|60|state switching command with timestamp CP56Time2a|
 +^C_SE_TA_1|61|setpiont command, normalized value with timestamp CP56Time2a <sup>2)</sup>|
 +^C_SE_TB_1|62|setpiont command, scaled value with timestamp CP56Time2a <sup>2)</sup>|
 +^C_SE_TC_1|63|setpiont command, floating point number with single precision and timestamp CP56Time2a <sup>3)</sup>|
 +^C_TD_NA_1|145|transparent data transmission(ABB D560)|
 +
 +===Control/Communication/Special functions===
 +^Name<sup>1)</sup>  ^Typ ^Description^
 +^M_EI_NA_1|70|end of initialization <sup>6)</sup>|
 +^C_IC_NA_1|100|general query<sup>6)</sup>|
 +^C_RD_NA_1|102|single query <sup>6)</sup>|
 +^C_CS_NA_1|103|clock-synchronisation <sup>6)</sup>|
 +^C_RP_NA_1|105|process-reset <sup>6)</sup>|
 +^C_TS_NA_1|107|test command with timestamp CP56Time2a|
 +^C_TD_NA_1|145|transparent data command (ABB)|
 +^M_TD_NA_1|146|transparent data report(ABB)|
 +
 +===Notes===
 +<sup>1)</sup> Name that is entered in the gateway as " format = " \\
 +<sup>2)</sup> require the specification of factor (F:xxx) and given if offset (O:xxx)\\
 +<sup>3)</sup> factor and offset can be specified optionally\\
 +<sup>4)</sup> possible values: 0=Transient, 1=Off, 2=On, 3=Unkown\\
 +<sup>5)</sup> possible values: 0=Off, 1=On, 2=Transient, 3=Unknown\\
 +<sup>6)</sup> not configurable, needed/used for internal communication only
 +
 ^Format:  ^Description^ ^Format:  ^Description^
 ^M_SP_NA_1|single event| ^M_SP_NA_1|single event|
Zeile 168: Zeile 220:
 LocalUnits          = 12,13,14,15\\ LocalUnits          = 12,13,14,15\\
  